The cable series of electric power:
The series of a set of cables of rubber:YZ YC YH
The series of electric wire of cloth
Coaxial cable series
 
BV
IEC 05 (BV)
Specified temperature: Specified voltage of 70 degrees: 300/500 Vs consult the standard: GB5023. 3 - 1997 conductors use the single root naked copper wire to marked and call 0 of cross-section. 5-1. Square 0 mm. The polyvinyl chloride is insulated It is even, easy to shell , easy to judge to insulate the thickness It use in it is inside and outside room it is the regular connect up( power, it light)

NOM.Area Of cond.mm2

COMPOSTION COND
FINISHED PRODUCT

MAX.COND.RESISTANCE
DC 20 °C

No./mm

THICKNESS mm

O.D. mm

APPROX.WEIGHT kg/km
0.5 1/0.8 0.6 2.00 8.72 36.0
0.75 1/0.97 0.6 2.17 11.39 24.5
1 1/1.13 0.6 2.33 14.2 18.1
BVR
BVR
Specified temperature: Specified voltage of 70 degrees: 450/750 Vs consult the standard: JB8734. 2 - 1998 conductors use the single root naked copper wire to stranded and mark and call 2 of cross-section. 5-16 square mm.s the polyvinyl chloride thickness easy to shell, not easy to cut out and use in room regular to connect up, even without being insulated without being insulated( power, it light)

NOM.Area Of cond.mm2

COMPOSTION COND
FINISHED PRODUCT

MAX.COND.RESISTANCE
DC 20 °C

No./mm

THICKNESS mm

O.D. mm

APPROX.WEIGHT kg/km
2.5 19/0.41 0.8 3.65 34.8 7.41
4 19/0.52 0.8 4.2 51.4 4.61
6 19/0.64 0.8 4.8 73.4 3.08
10 49/0.52 1.0 6.6 128.7 1.83
16 49/0.64 1.0 7.63 185.8 1.15
RVV
IEC 53 (RVV)
Specified temperature: Specified voltage of 70 degrees: 300/500 Vs consult the standard: GB5023. 3 - 1997 conductors are used and stranded, the tin-plated or naked copper wire is marked and calls 0 of cross-section. 75-2. Square ones, core polyvinyl chlorides insulate even easy to shelled , not easy to cut out and use for general power lines thickness insulation sheath polyvinyl chloride

NOM.Area Of cond.mm2
NO.OF COND.
COMPOSTION COND
FINISHED PRODUCT

MAX.COND.RESISTANCE
DC 20 °C

No./mm

THICKNESS mm

O.D. mm
THICKNESS mm
APPROX.WEIGHT kg/km
0.75 2 24/0.20 0.62 6.50 0.85 56.8 26.70
1 2 32/0.20 0.62 6.80 0.85 65.6 20.00
1.5 2 30/0.25 0.75 7.90 0.85 89.7 13.70
2.5 2 49/ 0.85 9.70 1.10 137.7 8.21
0.75 3 24/0.20 0.62 6.90 0.85 57.3 26.70
1 3 32/0.20 0.62 7.20 0.85 67.1 20.00
1.5 3 30/0.25 0.75 8.60 0.95 95.2 13.70
2.5 3 49/0.25 0.85 10.30 1.10 142.5 8.21
0.75 4 24/0.20 0.62 7.50 0.85 71.3 26.70
1 4 32/0.20 0.62 8.10 0.95 87.5 20.00
1.5 4 30/0.25 0.75 9.70 1.10 126.0 13.70
2.5 4 49/0.25 0.85 11.45 1.20 184.7 8.21
0.75 5 24/0.20 0.62 8.45 1.00 90.94 26.70
1 5 32/0.20 0.62 8.90 1.00 106.9 20.00
1.5 5 30/0.25 0.75 10.80 1.20 156.8 13.70
2.5 5 49/0.25 0.85 12.70 1.30 228.7 8.21
BVVB
BVVB
Specified temperature: Specified voltage of 70 degrees: 300/500 Vs consult the standard: JB8734. 2 - 1998 conductors use the single root naked copper wire or strand and mark and call 2 Xs 0 cross-sections. 75-6. Square 0 and 3 Xs 0 of mm.. 75-2. Square 5 mm. The polyvinyl chloride is insulated It is even, easy to shell , easy to judge to insulate the thickness It use in it is inside and outside room the regular it connect up( power, it light)

NOM.Area Of cond.mm2

COMPOSTION COND
FINISHED PRODUCT

MAX.COND.RESISTANCE
DC 20 °C

No./mm

THICKNESS mm

O.D. mm
THICKNESS mm
APPROX.WEIGHT kg/km
2X0.75 2X1/0.97 0.6 3.97X6.14 0.9 43.5 24.5
2X1.0 2X1/1.13 0.6 4.13X6.46 0.9 50.6 18.1
2X1.5 2X1/1.38 0.7 4.58X7.36 0.9 67.6 12.1
2X2.5 2X1/1.78 0.8 5.38X8.76 1.0 100.8 7.41
2X4 2X7/0.85 0.8 6.15X10.3 1.0 161 4.61
2X6 2X7/1.04 0.8 6.72X11.44 1.1 216 3.08
3X0.75 3X1/0.97 0.6 3.97X8.31 0.9 59.4 24.5
3X1.0 3X1/1.13 0.6 4.13X8.79 0.9 73 18.1
3X1.5 3X1/1.38 0.7 4.58X10.14 0.9 98.8 12.1
3X2.5 3X1/1.78 0.8 5.38X12.14 1.0 147.7 7.41

Copyright:Liao Yuan The Cable Co.,Ltd  http://www.liaoyuan-cn.com  Design:China Business